D9412GV2/D7412GV2 Operation and Installation Guide 8.0 On-Board Points

Figure 11: Wiring for Installation Using the Ademco AB-12 Bell/Housing

PHONE LINE SEIZED

1CLASS 2 TRANSFORMER

16.5VAC 40 VA 60 Hz Model D1640

Internally Fused - Do Not short

2Requires Unswitched Outlet

Do Not Share With Other Equipment

3+ AUX POWER

4BATTERY NEGATIVE ONLY

Maximum Charging

Current 1.4 Amps.

5BATTERY POSITIVE ONLY

6

RELAY A

PROGRAMMABLE

ALARM OUTPUTS

 

 

Terminals

7

RELAY B

7 & 8

Requires Optional

 

 

Model D136 Relay

8

RELAY C

In ALT ALARM

& SW AUX

 

 

 

9COMMON

10 EARTH GROUND

GROUND FAULT DETECT

Enabled

Disabled

 

PHONE

ON when

RED

LED

communicating

 

OFF when idle

 

PHONE LINE SEIZED

TIP

TELCO CORD RING

 

MODEL D161

TIP

RING

 

TELCO

D9412GV2

 

 

VOLTAGE RANGES

 

 

Open

3.7 - 5.0 VDC

 

 

Normal

2.0 - 3.0 VDC

 

 

Short

0.0 - 1.3 VDC

Point 1 Point 2

Point 3 Point 4

Point 5 Point 6

Point 7 Point 8

11

12

13

14

15

16

17

18

19

20

21

22

1

2

3

1 1  2  3  4  5  6 2 Manual backgroundManual background 3 Manual backgroundManual background 4 Manual backgroundManual background 5 Manual backgroundManual background 6

4

5

1 -

Bell

4 -

Bell tampers

2 - Inner bell box lining

5 -

220 k0.5 W EOL resistor (provided with the

3 -

Outer bell box

 

Ademco AB-12 Bell/Housing)