Using the Terminal Strip
Caution - AC induction: Avoid installing Zonex data wires and Zonex input (sensor loop) wires around any AC conduit, wiring, or electrical devices that emit fields of electromagnetic interference (EMI).

D9412GV2/D7412GV2 Operation and Installation Guide 9.0 Off-Board Points

A D8128D OctoPOPIT can be installed up to 61 m (200 ft.) from the control panel.

2.Connect the D8128D to the control panel:

Wire the D8128D to the terminal strip on the side of the POPEX Module (), or

Connect the D8128D using the Molex® connectors (P1 and P2). Refer to Using Molex® Connectors on page 46.

Using the Terminal Strip

Refer to Table 17, Figure 16 on page 44, and Figure 17 on page 45 when using the terminal strip to connect the D8128D OctoPOPIT to the control panel.

Table 17: Terminal Strip Connections

 

D8128D

 

 

D9412GV2

 

D7412GV2

 

Common

 

Terminal 23

Terminal 23

 

Out

 

 

Zonex 1 = Terminal 27

 

Terminal 27

 

 

 

 

 

Zonex 2 = Terminal 25

 

 

 

In

Zonex 1 = Terminal 28

Terminal 28

 

 

 

 

Zonex 2 = Terminal 26

 

 

 

+12 V

 

Terminal 24

Terminal 24

Bosch Security Systems, Inc. 5/05 F01U003641B

43