D9412GV2/D7412GV2 Operation and Installation Guide 10.0 Off-Board Relays

To install OctoRelays in the enclosure with the control panel:

1.Align the module with one of the mounting locations in the enclosure (refer to Figure 2 on page 9).

2.Using the screws provided with the module, secure the module in the enclosure.

Use the D137 Mounting Bracket or D9002 Mounting Skirt to install OctoRelays in enclosures with no available module mounting locations.

10.1.4 Wiring Connections

Power down the control panel to connect OctoRelays. Refer to Figure 20 on page 48 and Figure 21 on page 49.

Table 19: Number of D8128Ds Used with D8129s

 

 

If the number of

Do not connect more than

D8128Ds connected to a

this number of D8129s:

single Zonex bus is:

 

9

6

10

5

11

4

12

3

13

1

14

1

OctoRelays for Relays 1 to 64 connect to

Zonex 1, Terminal 28.

OctoRelays for Relays 65 to 128 connect to Zonex 2, Terminal 26 on the D9412GV2 only.

Only one OctoRelay is shown wired to each Zonex bus in Figure 20 on page 48and Figure 21 on page 49. Wire additional OctoRelays in parallel. Review Section 6.0 Power Outputs on page 25 for information about providing enough power for the relays.

The number of D8129 OctoRelays that can be connected to each Zonex terminal on the D9412GV2 control panels is limited by the number of D8128D OctoPOPITs connected.

Using D8129 OctoRelays and D8128D OctoPOPITs together on the same Zonex terminals is limited and depends on the number of D8128 OctoPOPITs and D8129 OctoRelays connected to a single Zonex Bus.

Refer to Table 19 for information about the maximum number of D8128Ds and D8129s you can connect to a single Zonex bus.

10.2D811 Arm Status Relay Module

The D811 Arm Status Relay Module allows the addition of a single off-board relay output to the system. Alarm output, auxiliary relay, sensor reset, arming status, point status, alarm memory, or remote functions can be assigned to the D811 relay output. It is not restricted to the Arming Status Mode only.

Relay Numbers for D811 Not Programmable: If the D811 is connected to Zonex 1, Terminal 28, use relay number 53 for the relay output. If the D811 is connected to Zonex 2, Terminal 26 on the D9412GV2, use relay number 117 for the relay output.

D811 Modules connect as shown in Figure 22 on page 51and Figure 23 on page 52. Review Section 6.0 Power Outputs on page 25 to ensure that enough power is provided for the powered devices that connect to the system. Refer to Relay Parameters in the D9412GV2/D7412GV2 Program Entry Guide

(P/N: F01U003636) for programming details.

D811 Restricted for Fire Systems: The D811 relay output is not supervised and cannot be used in fire or combined fire and burglary installations for primary indication devices.

10.2.1

Relay Output

 

Relay outputs can activate when you are

 

programming the control panel.

 

Disconnect equipment connected to relay

 

outputs when you perform this function.

Each D811 relay output provides a Form C dry contact rated for 1.0 A at 12 VDC. Normally-open, common, and normally-closed terminals are available. When an individual output is activated, continuity exists between the normally-open and common terminals. When the output is not activated, continuity exists between the normally-closed and common terminals.