Henny Penny OFE- 291 manual Filter Pump Motor Protector-Manual Reset

Models: OFE- 291

1 40
Download 40 pages 678 b
Page 18
Image 18
3-11. FILTER PUMP MOTOR PROTECTOR-MANUAL RESET

3-11. FILTER PUMP MOTOR PROTECTOR-MANUAL RESET

3-12. CLEANINGTHE FRYPOT

Model OFE- 291

The filter pump motor is equipped with a manual reset button, located on the rear of the motor, in case the motor overheats. If motor won’t run, wait about 5 minutes before attempting to reset this protective device to allow motor to cool. Remove the access panel on the left side panel of the unit to reset the button. It takes some effort to push the reset, and a screwdriver can be used to help reset the button.

To prevent burns caused by splashing shortening, turn the unit’s main power switch to the OFF position before resetting the filter pump motor’s manual reset protec- tion device.

After the initial installation of the fryer, as well as before every change of shortening, the frypot should be thoroughly cleaned as follows:

1.Turn the COOK/PUMP switch to OFF, and unplug unit from wall receptacle.

Moving the fryer or filter drain pan while containing hot shortening is not recommended. Hot shortening can splash out and severe burns could result.

The filter drain pan must be as far back under fryer as it will go, and the cover in place. Be sure the hole in the cover lines up with the drain before opening the drain. Failure to follow these instructions causes splashing of shortening and could result in personal injury.

3-18

703

Page 18
Image 18
Henny Penny OFE- 291 manual Filter Pump Motor Protector-Manual Reset