Model OFE- 291
(Continued)
underscore (“_”) indicates the input is not presently detected. A checkmark (“ ”) indicates the signal is detecting a normal input. Ablinking (“X”) indicates the signal is presently detected, but is detected as a
The V, H, D, S, F, P and M signals below are wired in series. The first signal missing out of this sequence generally causes all signals to the right of it to be missing as well.
Press to continue onto OUTP H* P_.
6. OUTP H* P_
This mode displays the status of components and outputs. If the output signal is detected, an identifying letter is displayed (see below), followed by an “*”. If the output is off, “_” is displayed.
“H” = Heat output
“P” = Pressure output (pressure fryers only) If heat is on, “H*” shows in display. If heat is off, “H_” shows in display. If controls senses a problem with the heat output, “H*” shows in display, with the “*” flashing.
If pressure is on, “P*” shows in display. If pressure is off, “P_” shows in display. If controls senses a problem with the pressure output, “P*” shows in display, with the “*” flashing.
Pressto view the amp “DRAW” status of each output. “H ” and “P ” in the display means the amps are good. A flashing “X” behind the H or P means too much current.
Press to view the No Connect/Ground (“NC/GND”) status of each output. This monitors a possible problem with the relays on the output PC board.
“H ” and “P ” in the display means everything on the output PC board is good. A flashing “X” behind the H or P means a problem exists.
Press to view the outputs and inputs (see step 10) together.
403 |