| Press | and “6. PMP_ AIR_” shows in display. | |
(Continued) |
|
|
|
| Press | to view the amp “DRAW” status of the pump motor | |
| output and air valve output. “PMP ” and “AIR ” in the | ||
| display means the amps are good. Aflashing “X” behind the | ||
| “PMP” or “AIR” means too much current. | ||
| Press | to view the No Connect/Ground (“NC/GND”) | |
| status of each output. This monitors a possible problem with | ||
| the relays on the output PC board. | ||
| Press | to continue onto the OIL TMP reading. | |
| 7. OIL TMP |
| |
| This step shows the present peanut oil temperature. The | ||
| display shows “7. OIL TMP (temp.)”. | ||
| Press | to continue onto the CPU TMP reading. | |
| 8. CPU TMP |
| |
| This step shows the present PC board temperature. | ||
| Press | to continue onto the ANALOG reading. | |
| 9. ANALOG <1> 2.86V |
| |
| This step displays the present status of any channel of the | ||
| controller’s a to d converter. This feature may be useful to a | ||
| technician troubleshooting a problem with the fryer or | ||
| controller. |
| |
| The displayed value can be toggled between volts and bits | ||
| by pressing . If the displayed value has a decimal point, | ||
| it is voltage (0 to 5 VDC). If no decimal point is shown, the | ||
| value is | ||
|
| Press and hold | to exit Information Mode at any |
|
| time, or after 2 minutes, controls automatically exit | |
|
| back to normal operation. | |