Model OFE- 291

3-18. INFORMATION MODE

4. REVIEW USAGE

(Continued)

Press to view the accumulated information since the data

 

was manually reset:

FUNCTION

DISPLAY EX:

Day the usage data was previously reset

SINCE

APR-19

Number of hours the fryer was on

PWR ON HRS

 

165

Number of times oil was filtered

FILTERED

 

34

Total number of cook cycles

TOTAL CK

 

462

Cook Cycles stopped before “DONE”

QUIT COOK

 

4

Percentage of Cook Cycles before oil change

OIL WEAR -A-

73%

Percentage of hours before oil change

OIL WEAR -B-

47%

Cook Cycles for Product #1

COOKED -1- 193

Cook Cycles for Product #2

COOKED -2- 107

Cook Cycles for Product #3

COOKED -3-

58

Cook Cycles for Product #4

COOKED -4-

0

Cook Cycles for Product #5

COOKED -5-

13

Cook Cycles for Product #6

COOKED -6-

69

Cook Cycles for Product #7

COOKED -7-

0

Cook Cycles for Product #8

COOKED -8-

7

Cook Cycles for Product #9

COOKED -9-

15

Cook Cycles for Product #0

COOKED -0-

0

Reset usage data:

 

 

 

Enter the Mgr Code (1, 2, 3 unless changed)

 

 

 

on this step to zero out all the usage

RESET USG/

 

 

information.

ENTER CODE----

Press

to continue to INP A_CVHDSF_M

 

5. INP A_CVHDSF_M

Press

to view the status of components and inputs. If the

input signal is detected, an identifying letter is displayed (see below). If the signal is not detected, “_” is displayed.

With the COOK/PUMP switch in the COOK position, and all inputs detected, “H_ P_ A_CVHDSF_M” shows in the display. See below for “definition” of codes.

A = COOK/PUMP in COOK position. B = COOK/PUMP in PUMP position

C = Solenoind continuity; won’t show on open fryers V = Volts - 24 VAC detected

H = High Limit - If “H” is present, the high limit is good; if “H” is missing, the high limit is tripped (overheated) or faulty

D = DRAIN SWITCH-If “D” is present, the drain handle is closed; if “D” is missing, the drain is open or faulty

S = COOK/PUMP switch ON interlock circuit: If “S” is

 

present, the COOK/PUMP switch is in the COOK position.

 

If the “S” is missing, the COOK/PUMP is either off, failed,

 

or wired incorrectly

 

F = FAN

1005

M = MV-Detects 24 V jumper to MV terminal

3-38

Page 38
Image 38
Henny Penny OFE- 291 manual Information Mode, Function Display EX