D9412GV2/D7412GV2 Operation and Installation Guide 14.0 Faceplates
14.0Faceplates
14.1D9412GV2 Faceplate
Figure 32: D9412GV2 Faceplate
F01U003643B
1
2
LEDs Off When Normal | D9412GV2 |
| |
YEL | Charging Status |
| |
|
| Digital Alarm Communicator Transmitter | SDI Connector |
| Low Battery - 12.1 VDC |
| |
RED | Refer to D9412GV2/D7412GV2 Approved Applications Compliance Guide (P/N: F01U003639___) |
| |
|
| For System Wiring Diagram, Issue A | Reset Pin |
10.2 VDC - Battery Load Shed | Refer to D9412GV2/D7412GV2 Approved Applications Compliance Guide (P/N: F01U003639___) | Disable all except Battery | |
Charging and Programming | |||
|
| For Compatible Smoke Detectors |
|
11
3
4
5
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| POWER SUPPLY REQUIREMENTS |
|
|
|
|
|
| ||||||||||
|
|
| CLASS 2 TRANSFORMER | The Power Supply provides a maximum of 1.4 Amps for the Control Panel and all | ||||||||||||||||||||||||||||||||
|
|
| 16.5 VAC 40 VA 60 Hz | Accessory Devices. For System Loading, refer to D9412GV2/D7412GV2 | ||||||||||||||||||||||||||||||||
|
|
| Model D1640 |
|
|
|
|
|
| Operation and Installation Guide (P/N: F01U003641___). |
|
|
|
|
|
| ||||||||||||||||||||
|
|
| Internally Fused - Do not short | All external connections except Terminal 5 | (battery positive) are inherently power | |||||||||||||||||||||||||||||||
|
|
| Requires Unswitched Outlet | |||||||||||||||||||||||||||||||||
|
|
| Do not share with other equipment | limited. Requirements for battery standby time might reduce allowable output. | ||||||||||||||||||||||||||||||||
|
|
| + AUX POWER |
|
|
|
|
|
| CAUTION: See D9412GV2/D7412GV2 Operation and Installation Guide | ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| (P/N: F01U003641) for Power Requirements relating to Terminals 6 and 7 . | |||||||||||||||||||||||
|
|
| BATTERY NEGATIVE ONLY | WARNING! |
|
|
|
|
|
|
| Battery: Replace every 3 to | ||||||||||||||||||||||||
|
|
| CAUTION: Avoid damage to Panel. |
| ||||||||||||||||||||||||||||||||
|
|
| Do not connect 24 V to terminals. | Model D122/D122L Dual Battery |
| 5 years with one or two Model | ||||||||||||||||||||||||||||||
|
|
| Maximum charging current 1.4 A | Harness. Improper installation can |
| D126 12V 7Ah or D1218 | ||||||||||||||||||||||||||||||
|
|
| BATTERY POSITIVE ONLY | be a fire hazard. |
|
|
|
|
|
|
| 12V 18Ah Lead Acid Batteries. | ||||||||||||||||||||||||
|
|
| RELAY A | PROGRAMMABLE | This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) | |||||||||||||||||||||||||||||||
|
|
| and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station, Proprietary and | |||||||||||||||||||||||||||||||||
|
|
| ALARM OUTPUTS | |||||||||||||||||||||||||||||||||
|
|
|
|
|
| Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction | ||||||||||||||||||||||||||||||
|
|
|
|
|
| Terminals | ||||||||||||||||||||||||||||||
|
|
|
|
|
| (National Fire Protection Association, Battermarch Park, Quincy, MA 02269). Printed information | ||||||||||||||||||||||||||||||
|
|
| RELAY B | 6 | and 7 | |||||||||||||||||||||||||||||||
|
|
| describing proper installation, operation, testing, maintenance, evacuation planning and repair | |||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||
|
|
|
|
|
| SWITCHED AUX | service is to be provided with this equipment. |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
| RELAY C | Terminal | D9412GV2 Control/Communicator is UL Listed For Central Station, Local, Remote Station and | |||||||||||||||||||||||||||||||
|
|
|
| 8 |
|
|
|
|
| Household Fire Alarm, and Central Station, Local, Police Station Connect, Household Burglar Alarm | ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| and Encrypted Line Security when communicating via a network. |
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| System is intended to be checked by a Qualified Technician at least every 3 years. | |||||||||||||||||||||||
|
|
| COMMON |
|
|
|
|
|
| The types of initiating circuits the panel has been approved for are A, M, W, SS. | ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VOLTAGE RANGES | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
| EARTH GROUND |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Open |
|
| 3.7 - 5.0 VDC | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Normal |
|
| 2.0 - 3.0 VDC | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Short |
|
| 0.0 - 1.3 VDC | |||||
|
| GROUND FAULT DETECT |
| Point 1 Point 2 |
| Point 3 Point 4 |
| Point 5 Point 6 |
| Point 7 Point 8 | ||||||||||||||||||||||||||
|
|
|
|
|
| Enabled |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
| Disabled |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
| PHONE | ON when |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
| RED | communicating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| LED | OFF when idle |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| PHONE LINE SEIZED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| TIP | TELCO CORD RING | 11 | 12 13 | 14 15 16 | 17 18 19 | 20 21 22 | |||||||||||||||||||||||||
|
|
|
|
|
| MODEL D161 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PERIPHERAL DEVICE CONNECTIONS
RED | POWER + |
|
YELLOW | DATA BUS A |
|
GREEN | DATA BUS B |
|
BLACK | COMMON |
|
N.F.P.A. | ZONEX OUT 1 |
|
Style 3.5 |
|
|
Signaling |
|
|
Line |
|
|
Circuits | ZONEX IN 1 |
|
| ZONEX OUT 2 | 26 |
| ZONEX IN 2 | 25 |
ZONEX POWER + | 24 | ||
ZONEX COMMON | 23 | ||
Point 8 | D5200/D5360 | ||
S3 Option | PROG CONN | ||
Closed = 1KΩ EOL |
|
|
|
|
|
| |
Normal Operation |
|
|
|
Open |
|
|
|
Bell Box 220 KΩ |
|
|
|
GRN |
|
|
|
|
|
|
|
10
PHONE LINE
SEIZED
TIP | RING |
| TELCO |
6 | 7 | 8 | 9 |
1 - | Charging status LED (yellow) | 7- Point 8 ground fault detect enable/disable | |
2 - | Low battery LED (red) | 8- Operation monitor LED (green) | |
3 - | 9- | Accessory connector | |
4 - | Ground fault detect enable | 10- | Programming connector |
5- | Phone LED (red) | 11- | Reset pin |
6 - | Telephone cord connector |
|
|