D9412GV2/D7412GV2 Operation and Installation Guide 9.0
Table 15: D8128D OctoPOPIT Switch Settings for D9412GV2 and D7412GV2
ZONEX 1 | D8128D Address Switches |
| ZONEX 2 | |||
Points 9 to |
|
|
|
|
| Points 129 |
127 | 1 | 2 | 3 | 4 | 5 | to 247 |
9 to 16 | ON | ON | ON | ON | * | 129 to 136 |
17 to 24 | ON | ON | ON | OFF | * | 137 to 144 |
25 to 32 | ON | ON | OFF | ON | * | 145 to 152 |
33 to 40 | ON | ON | OFF | OFF | * | 153 to 160 |
41 to 48 | ON | OFF | ON | ON | * | 161 to 168 |
49 to 56 | ON | OFF | ON | OFF | * | 169 to 176 |
57 to 64 | ON | OFF | OFF | ON | * | 177 to 184 |
65 to 72 | ON | OFF | OFF | OFF | * | 185 to 192 |
73 to 80 | OFF | ON | ON | ON | * | 193 to 200 |
81 to 88 | OFF | ON | ON | OFF | * | 201 to 208 |
89 to 96 | OFF | ON | OFF | ON | * | 209 to 216 |
97 to 104 | OFF | ON | OFF | OFF | * | 217 to 224 |
105 to 112 | OFF | OFF | ON | ON | * | 225 to 232 |
113 to 120 | OFF | OFF | ON | OFF | * | 233 to 240 |
121 to 127 | OFF | OFF | OFF | ON | * | 241 to 247 |
*Line Termination Switch
For the D8128D OctoPOPITs assigned to Points 121 to 127, 241, and 247, set Point Input Switch 8 to the OPEN position.
D9412GV2 uses Points 9 to 127 on Zonex 1 and Points 129 to 247 on Zonex 2.
D7412GV2 uses Points 9 to 75 on Zonex 1 only.
Table 16: Switch 5 Settings for Line Termination
|
|
|
|
|
|
|
Is a D8125 |
|
|
|
| ||
POPEX Module |
|
|
| Switch 5 Setting(s) on | ||
connected? | Zonex No. | D8128D OctoPOPIT(s) | ||||
|
|
|
|
|
|
|
| No |
|
| NA |
| Set Switch 5 of only |
|
|
|
| one D8128D to ON | ||
|
|
|
|
|
| |
| Yes | 1 |
| Set Switch 5 of all | ||
|
| D8128Ds to OFF | ||||
|
|
|
|
|
| |
| No |
|
| NA |
| Set Switch 5 of only |
|
|
|
| one D8128D to ON | ||
|
|
|
|
|
| |
| Yes | 2 |
| Set Switch 5 of all | ||
|
| D8128Ds to OFF | ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
Point DIP Switches
Each point connected to the D8128D is enabled by closing the respective DIP switch, or disabled by opening the DIP switch. For example, to disable a device connected to the P3 Terminal (Point 3), move DIP switch number 3 to the OPEN position.
Use the point DIP switches to disable conflicting points, such as when a D9210B Access Control Module must be assigned to a point that falls within the range of the D8128D OctoPOPIT. In this example, a D9210B is assigned to Point 20. On the same system, a D8128D OctoPOPIT is assigned to Points 17 through
24.Moving the DIP switch for Point 4 to the OFF position would effectively disable Point 20, allowing normal operation of the D9210B and the OctoPOPIT.
Terminate each OctoPOPIT sensor loop with a 1 kΩ EOL resistor. Attach a resistor even if you do not enable the loop.
9.4.5Mounting OctoPOPITs
The D8128D OctoPOPIT Module can be installed in the enclosure with the control panel using standard
0.8mm (22 AWG) wire. If using the D125B or D129, refer to the Specifications section of the D8128D Installation Guide (P/N: 41323) for cabling requirements.
For UL Listed systems, mount the D8128D in a
1.Align the OctoPOPIT module using any of the four mounting locations in the enclosure. Refer to Figure 2 on page 15.
2.Use the screws provided with the module to secure it in the enclosure.
9.4.6 | Wiring OctoPOPITs |
| Warning: Disconnect all power to the |
| control panel before beginning any work |
| with the internal components. Serious injury |
| could result from electrical shock. |
1.Power down the control panel:
a.Disconnect the positive (red) battery lead at the battery.
b.Unplug the transformer.
42 | Bosch Security Systems, Inc. 5/05 F01U003641B |