Alarm output is switched in case of power failure

512

___

Extrusion mode . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . 1024 ___

Printer available . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . .16348

____

Configuration value:

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

_____

Example:

 

 

 

Level probes: raw material and additive probes installed

Throughput: 8000 g/min

Totalizer displayed in lbs

Extrusion mode

Raw material probe

. . . . . . . . . 1

 

1

 

 

 

Additive

 

probe

. . . . . . . . . 2

 

2

 

 

 

 

Blending

unit

. . . . . . . . . 8

__

 

 

Totalizer

 

displayed in lb

. . . . . . . . .16

16

 

 

Throughput

. . . . .1-6500 g/min

. . . . . . . . . 0

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Throughput

(1-6500 g/min) X 10

. . . . . . . . . 32

32

 

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Throughput

(1-6500 g/min) / 10

. . . . . . . . . 128

___

External

run/stop signal controls dosing

. . . . . . . . . 64

___

Mounting

on a Mico mixing-hopper

. . . . . . . . . 256

___

Alarm

output switched in case of power failure

. . . . . . . . .512

___

Extrusion

mode

. . . . . . . . 1024

1024

Printer

available

. . . . . . . . 16348 ____

Configuration value:

1075.

Injection Molding: