17.Install the dosing container along with the dosing hopper on the dosing housing (pay attention to the guide pins).
18.Mount the profile clamp.
19.Mount the screw at the profile clamp and tighten.
5.7Exchangeable Stations
Dosing discs of the same type may be exchanged for each other without any problems. If dosing discs with a different compartment number are installed, this has to be entered in the control system.
1.Enter the (preliminary) calibration value of the freshly installed dosing disc (*=bulk density 550g/l, ** = bulk density 700g/l).
2. Execute “calibration” to determine the final calibration value.
5.8Replacing Fuses
1.Stop the continuous operation.
2.Wait until the dosing unit has come to a standstill.
3.Switch off the device by means of the on/off switch.
4.Cut off the voltage supply.
5.Wait at least one minute before starting to work at the switching cabinet.
Digital Dosing Units | 41 |