If a current signal is available (0 - 20 mA) calculate the frequency output of the extruder for the lower / upper working area using the formula:
Frequency [Hz] = Input current [mA] x 10000 [Hz]
| 20 [mA] |
Note the data: |
|
Min. input frequency = __________ Hz |
|
Max. input frequency = __________ Hz |
|
Calculate the span factor using the formula: |
|
Span factor [Hz / rpm] = | Frequency [Hz]____________ |
| Rotational speed of the extruder [rpm]x 10 |
Note the data:
Span factor = __________
Determining the Configuration Value
Extrusion (Constant or Proportional):
Mark the functions required. Use the numerical value indicated and insert it in the empty field if applicable. Total the figures for configuration value.
Optional raw material level probe installed | . . . . . . . . . . . . . 1 | ___ |
Optional additive level probe installed | . . . . . . . . . . . . .2 | ___ |
Optional blending unit installed | . . . . . . . . . . . . . 8 | ___ |
Totalizer displayed in lb (kg default) | . . . . . . . . . . . . . 16 | ___ |
Extruder throughput | . . . . . . . . . . . . . 0 |
|
or |
|
|
Extruder throughput | . . . . . . . . . . . . 32 | ___ |
or |
|
|
Extruder throughput | . . . . . . . . . . . . .128 | ___ |
(NOTE: the throughput selections above determine placement of the decimal point on the
display) |
|
|
External run/stop signal controls dosing | 64 | ___ |
Mounting on Mico mixing hopper | 256 | ___ |
Digital Dosing Units | 48 |