Stovax Studio 22 flame failure device, running in, servicing, ventilation, installation details

Models: Studio 22

1 39
Download 39 pages 10.91 Kb
Page 8
Image 8
6.flame failure device

USER INSTRUCTIONS

12

D

A

AR2124

5.6Put the groove in the base of Log E into the indent on the right of Log A. The left branch rests on the upper end of Log

C, Diagram 13.

13

E

A

AR2125

5.7Log F rests against Log B at its far right end, between Log B and the side panel. The front end of Log F sits on the front panel, see Diagram 14

14

B

F

AR2126

You must ensure the door catches are fully engaged:

Slide the allen key into the gap between the door and frame and locate the catch of the lower lock

Push the allen key DOWN

Slide the allen key into the gap and locate the upper lock

Push the allen key UP

6.flame failure device

6.1This is a safety feature incorporated on this appliance which automatically switches off the gas supply if the pilot goes out and fails to heat the thermocouple.

7.running in

7.1The surface coating on the metal used in your GAZCO fire will "burn off" during the first few hours of use producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice.

8.servicing

8.1The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence always quote the Model number and the Serial number which may be found on the data badge.

9.ventilation

9.1Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction.

10.installation details

10.1Your installer should have completed the commissioning sheet at the front of this book. This records the essential installation details of the appliance. In all correspondence always quote the Model number and Serial number.

11.HOT SURFACES

11.1Parts of this appliance become hot during normal use.

Regard all parts of the appliance as a ‘working surface’

Provide a suitable fire guard to protect young children and the infirm

12.FIRE WILL NOT LIGHT

12.1If you cannot light the Studio:

Check that the emergency shut off switch is in the ON

(1) position, see Section 2, Emergency Shut Off

Check and change the batteries in the remote handset

Check and change the appliance batteries, Section 4. Consult your Gazco dealer if the Studio still does not light.

8

Page 8
Image 8
Stovax Studio 22 manual flame failure device, running in, servicing, ventilation, installation details, Hot Surfaces