Step I Part to remove

Step I Part to remove

Recoil starter

I housing

5Oil sensor (Option)

I

I

Procedures

I

(1)Remove recoil from blower- - housing.

M6 X 8mmflange bolt 4pcs.

(1)Remove blower housing from crankcase.

M6X i2mm flange bolt

4pcs.

(1)Remove oil sensor probe. Be careful not to damage stick and sensor since these are sensitive and an erratic operation may result.

Remarks I Tool

1Omm box wrench

lOmm box wrench

BLOWER HOUSING

Fig. 5-4