Step I Part to remove
Recoil starter
I housing
5Oil sensor (Option)
I
I | Procedures | I |
(1)Remove recoil from blower- - housing.
M6 X 8mmflange bolt 4pcs.
(1)Remove blower housing from crankcase.
M6X i2mm flange bolt | 4pcs. |
(1)Remove oil sensor probe. Be careful not to damage stick and sensor since these are sensitive and an erratic operation may result.
Remarks I Tool
1Omm box wrench
lOmm box wrench
BLOWER HOUSING
Fig.
- 19 -