4-4) CHECKING FUNCTIONAL MEMBERS
(1)STATOR
Measure the winding wire resistance. Check the resistance of the wires that comes out from the stator using a tester, referring to the following table.
NOTE: When measuring according the numerical value shown in the chart, tolerance should be considered because the inaccuracy of the tester. If an accurate value is needed, measure by electric resistance using an
While doing this, use caution to avoid contact resistance.
Generator wire resistance |
| Unit;Ω |
AC 120V | AC 230V | AC 240V |
Color of the wires Specification | Specification | Specification |
| 1.2 | 4.2 | 4.2 | |
4P Connector (AC output line) | 1.2 | 4.2 | 4.2 | |
| ||||
| 1.2 | 4.2 | 4.2 | |
Diode Rectifier Connector | 0.2 | 2.1 | 2.1 | |
(2)INVERTER UNIT |
|
|
|
|
Check if there is no color change or blister on the |
|
|
| |
filling resin, and confirm that there is no damage or |
|
|
| |
color change in the electrical parts, electrical wires, |
|
| White | |
or the connectors. |
|
|
| |
|
| a | c | |
And, check the resistance at the 2P connector for |
| |||
| b | Red | ||
AC output and at the 4P connecter for the stator |
| d | ||
| Stator wire |
| ||
wire terminals. |
|
|
| |
|
| terminal | 2P connector | |
|
|
|
| |
|
|
|
| for AC output |
Stator wire Terminal
|
|
| Apply red needle of the circuit tester | |||
|
|
|
|
|
|
|
|
|
| a | b | c | d |
|
|
|
|
|
|
|
needleblack | testercircuit | a | ーーー | 5 MΩ~ | 4 MΩ~ | 4 MΩ~ |
|
| |||||
|
|
|
|
|
|
|
|
| b | 2.5 MΩ~ | ーーー | 10 MΩ~ | 10 MΩ~ |
|
|
|
|
|
|
|
Apply | of the | c | 2.5 MΩ~ | 10 MΩ~ | ーーー | 10 MΩ~ |
|
|
|
|
| ||
d | 2.5 MΩ~ | 10 MΩ~ | 10 MΩ~ | ーーー | ||
|
|
|
|
|
|
|
2P Connector for AC output
| Red | White |
|
|
|
Red | ーーー | 0.57 kΩ |
White | 0.57 kΩ | ーーー |