(4)RECEPTACLE, AC PLUG
Check burn marks in the areas where electric current flows, such as wire and plastic parts of AC receptacle.
(5)OIL SENSOR
Confirm that there is a sufficient amount of oil.Measure continuity between the wires of oil sensor and the crankcase using a circuit tester.
Below the lower level : ON (continuity) | 0Ω |
Above the lower level : | ∞ |
Use
Oil capacity : 0.4 liters
Oil Sensor