Subaru Robin Power Products R1700i service manual Troubleshooting, No output power or Lower output

Models: R1700i

1 52
Download 52 pages 54.96 Kb
Page 45
Image 45
6.TROUBLESHOOTING

6.TROUBLESHOOTING

No output power or Lower output

When engine is running,

check if Overload Lamp is activated

Turned off

Turned on

Remove any electric load equipment that is connected

Once stop the engine, and reset the overload warning

When engine is running,

check if the Pilot Lamp is turned on Voltage exceeds rated range

Turned off

Within the rating

Measured resistance value

Red

White

Blue

Generator

Confirm the engine revolutions (turn the APS sw to OFF) correct revolution 41004300rpm

Low, High

Go to the "Engine does not start (Start failure)" (refer to p. 44)

Measured resistance value between

Red-white

) (Refer to the figure below)

White-blue

Red-blue

Abnormal

Change the generator

Change INV C/U

Resistance value of the generating main body for reference

 

 

 

Unit : Ω

 

Red - Blue

Blue - White

White - Red

 

 

 

 

AC120V

1.2

1.2

1.2

AC230V/240V

4.2

4.2

4.2

 

 

 

 

 

 

Surrounding temperature 20

– 42 –

Page 45
Image 45
Subaru Robin Power Products R1700i service manual Troubleshooting, No output power or Lower output