5-2-2 CONDENSER

One or two condensers are installed in the con- trol box and are connected to the condenser coil of the stator.

These condensers and condenser coil regulate the output voltage.

Fig. 5-3

5-2-3 ROTOR

The rotor consists of a laminated silicon steel sheet core and a field coil which is wound over the core.

DC current in the field coil magnetizes the steel sheet core. Two permanent magnets are provided for the primary exciting action.

Fig. 5-4

A diode rectifier and surge absorber is mounted inside of the insulator.

Fig. 5-5A

Fig. 5-5B

- 11 -

Page 14
Image 14
Subaru Robin Power Products RGV6100, RGV4100 service manual Condenser, Rotor