NORMAL CAPACITY OF CONDENSER

RGV2800

RGV4100

RGV6100

 

 

 

24μF

20μF x 2

28μF x 2

 

 

 

 

Table. 9-3

 

*If such an instrument is unavailable, the condenser can be checked by replacing with a new one. If the generator performs good with new condenser, the cause of trouble is defect in original condenser.

9-7 DIODE RECTIFIER

Fig. 9-7

Fig. 9-8

Circuit inside of the diode rectifiers is as shown in Fig. 9-7. Check continuity between each terminal by using a circuit tester as shown in Fig. 9-8. The rectifier is normal when condtinuity is as follows:

* Checking table for analogue circuit tester.

Analogue circuit tester

Apply black (minus) needle of the circuit tester

 

 

 

 

Brown

Brown

Orange

Brown / White

 

 

 

 

 

 

 

 

 

Brown

---------

No continuity

No continuity

Continuity

 

 

 

 

 

 

Apply red (plus) needle of

Brown

No continuity

---------

No continuity

Continuity

 

 

 

 

 

the circuit tester

Orange

Continuity

Continuity

 

Continuity

 

---------

 

Brown / White

No continuity

No continuity

No continuity

---------

 

 

 

 

 

 

 

 

Table. 9-4-1

 

 

 

- 35 -