8-1-2 INSTRUMENTS

(1)VOLTMETER

AC voltmeter is necessary. The approximate AC voltage ranges of the voltmeters to be used for various types of generators are as follows:

0 to 150V : Type with an output voltage of 110 or 120V

0 to 300V : Type with an output voltage of 220, 230 or 240V

0 to 150V, 0 to 330V : Dual voltage type

(2)AMMETER

AC ammeter is necessary. An AC ammeter with a range that can be changed according to the current rating of a given generator is most desirable. (About 10A, 20A, 100A)

(3)FREQUENCY METER

Frequency range : About 45 to 65Hz

NOTE : Be careful of the frequency meter’s input voltage range.

Fig. 8-2

Fig. 8-3

Fig. 8-4

- 27 -

Page 30