5-2-4 NO-FUSE BREAKER

The no-fuse breaker protects the generator from getting damage by overloading or short circuit in the appliance. Table 5-1 shows the capacity of no-fuse breaker by each spec. and their object of protection.

MODEL

SPECIFICATION

NO-FUSE BREAKER

OBJECT or PROTECTION

 

 

 

 

RGV2800

60 Hz-120V

20 A

Total output amperage

 

 

 

 

RGV4100

60 Hz-120 V/ 240V

15 A (2-Pole, 2-Element)

Total output amperage

 

 

 

 

 

 

20 A (2-Pole, 2-Element)

Total output amperage

RGV6100

60 Hz-120 V/ 240V

 

 

30 A

Output from 30A receptacle

 

 

 

 

 

 

Table. 5-1

5-2-5 DC CIRCUIT BREAKER

The 10 ampere DC circuit breaker mounted on the control panel protects whole DC circuit from getting damage by overload or short circuit.

Fig. 5-6

5-2-6 RECEPTACLE and AC PLUG (STD. SPEC.)

These are used for taking AC output power from the generator. A total of six kinds of receptacles, each varying in rated voltage and current from another, are used. Each model has at least one receptacle to deliver the rated generator output. As many AC plugs as the receptacles, each matching the correspond- ing receptacle, are provided. Table 5-2 shows the rated current for each receptacle. Be careful not to use the receptacles and AC plugs beyond the specified amperage limits to prevent burning.

- 12 -

Page 15
Image 15
Subaru Robin Power Products RGV4100, RGV6100 NO-FUSE Breaker, DC Circuit Breaker, Object or Protection, RGV2800