(4)Check the wiring through ZCT on the IDLE CONTROL UNIT.

*Single Voltage Type

Make sure that an output wire from main coil is passing through the ZCT on the IDLE CONTROL UNIT.

* Dual Voltage Type

Check that two output wires (black wire and red wire) from main coils are passing through the ZCT on the IDLE CONTROL UNIT in the same direction.

(5)Checking the IDLE CONTROL UNIT

Check the resistance between five leads of IDLE CONTROL UNIT with circuit tester.

54

12 3

Terminal number of

the IDEL CONTROL UNIT

Fig. 11-16A

IDEL CONTROL UNIT

OUTPUT WIRE

ZCT

Fig. 11-15

Fig. 11-16B

Circuit tester (with battery

 

Apply black (minus) needle of the circuit tester

 

 

 

 

 

 

 

 

power source 1.5 V)

 

 

 

 

 

 

 

 

 

1

 

2

3

4

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

-----------

 

250 kΩ

250 kΩ

 

75 kΩ

 

 

 

 

 

 

 

 

 

 

 

 

2

 

-----------

 

Apply red (plus) needle

 

 

 

 

 

 

 

 

 

 

3

250 kΩ

 

 

250 kΩ

 

75 kΩ

of the circuit tester

 

 

-----------

 

 

 

 

 

 

 

 

 

 

 

 

4

250 kΩ

 

250 kΩ

-----------

 

75 kΩ

 

 

 

 

 

 

 

 

 

 

 

 

5

8.5 kΩ

 

7.8 kΩ

7.8 kΩ

 

-----------

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table. 11-4

 

 

 

 

NOTE : The resistance readings vary depending on the types of circuit testers. The above table shows an example of the resistance readings measured by an ordinary analogue circuit tester with 1.5 volt battery power source. It is advisable for you to check the resistance readings using your standard circuit tester and revise the checking table.