Powering On and Off the Server

Powering On and Off the Server

You have to apply only standby power to the server at this point so that you can perform initial configuration o f the service processor. Procedures for powering on to main power mode and for shutting down from main power mode are also included in this section.

Applying Standby Power for Initial Service Processor Configuration

Use this procedure to apply standby power to the service processor (SP) before initial configuration.

Caution – Do not operate the server without all fans, component heatsinks, air baffles, and the cover installed. Severe damage to server components can occur if operated without adequate cooling mechanisms.

1.Connect grounded AC power cords to the AC power connectors on the back panel of the server and to grounded AC power outlets.

In standby power mode, the Power/OK LED on the front panel flashes, indicating that the SP is working. See FIGURE 1-13or FIGURE 1-14for the LED location.

Note – At this point, standby power is supplied only to the Graphics Redirect and Service Processor (GRASP) board and power supply fans. You can proceed to Chapter 2 to begin initial configuration. Do not apply main power to the rest of the server until you are ready to install a platform operating system.

2.Continue with initial software setup tasks, as described in Chapter 2.

16 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007