SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual

Installing the Server into the Rack

Installing the Chassis into a Rack (Figure 2-3)

1.Confirm that chassis includes the inner rails and rail extensions . Also, confirm that the outer rails are installed on the rack.

2.Line chassis rails with the front of the rack rails.

3.Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). When the server has been pushed completely into the rack, you should hear the locking tabs "click".

4.(Optional) Insert and tightening the thumbscrews that hold the front of the server to the rack.

Installing the Server into a Telco Rack

To install the 6016T-6RFT+/6016T-6RF+ into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total).

1.First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it.

2.Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the telco rack.

3.Finish by sliding the chassis into the rack and tightening the brackets to the rack.

Note: Figure is for illustrative purposes only. Always install servers to the bottom of a rack first.

Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.