SUPER MICRO Computer 1.0a user manual Control Panel LEDs, UID/Overheat/Fan Fail/Power Fail

Models: 1.0a

1 124
Download 124 pages 34.74 Kb
Page 26
Image 26

SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual

3-3 Control Panel LEDs

The control panel located on the front of the SC819TQ chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.

UID/Overheat/Fan Fail/Power Fail

Blue: This LED turns on when either the front or the rear UID button is pushed. Pushing either button a second time will turn this LED off.

Red: When this LED flashes quickly it indicates a fan failure. When flashing slowly it indicates a power supply failure. When on continuously (on and not flashing) it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain flashing or on as long as the overheat condition exists.

2

NIC2

Indicates network activity on GLAN2 when flashing .

1

NIC1

Indicates network activity on GLAN1 when flashing.

HDD

Indicates IDE channel activity. On the 6016T-6RFT+/6016T-6RF+ this light indicates HDD and/or DVD-ROM drive activity when flashing.

3-2

Page 26
Image 26
SUPER MICRO Computer 1.0a user manual Control Panel LEDs, UID/Overheat/Fan Fail/Power Fail