SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual

2-5 Installing the System into a Rack

This section provides information on installing the 6016T-6RFT+/6016T-6RF+ into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails

You should have received two rack rail assemblies in the rack mounting kit. Each assembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of the outer rails are also included.

Installing the Inner Rails

Both the left and right side inner rails have been pre-attached to the chassis. Pro- ceed to the next step.

Figure 2-1. Identifying the Sections of the Rack Rails

(left side rail shown)

Inner Rail

Locking Tab

Outer Rail

Warning: do not pick up the server with the front handles. They are de- signed to pull the system from a rack only.

2-4

Page 18
Image 18
SUPER MICRO Computer 1.0a user manual Installing the System into a Rack, Identifying the Sections of the Rack Rails