SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual

BMC Heartbeat LED

A BMC heartbeat LED is located at LED3 on the serverboard. When LED3 is blinking, the BMC is functioning normally.

SAS Activity & SAS Heartbeat LEDs

A SAS Activity LED (LED 4) and a SAS Heartbeat LED (LED 5) are provided on the serverboard. When LED 4 is blink- ing, the SAS connections are active. When LED 5 blinks, SAS is functioning normally.

SAS Error LED

A SAS Error LED is designated LED6 on the serverboard. When LED6 is on, a SAS error has occurred. See the table at right for more information.

 

BMC Heartbeat LED

 

 

 

State

 

Definition

Blink-

 

BMC: Normal

 

ing

 

 

 

 

 

SAS Activity & SAS Heartbeat LEDs

LED

State

 

Definition

LED 4

Blink-

 

SAS Active

 

 

ing

 

 

LED 5

Blink-

 

SAS

 

 

ing

 

Normal

 

 

 

 

SAS Error LED

LED

State

 

Definition

LED 6

On

 

SAS Error Oc-

 

 

 

 

curred

 

 

 

 

TLAN LED (X8DTU-6TF+ only)

A TLAN (10GbLAN) LED is located at LED7. When this LED is yellow, the LAN port is connected and/or active. When this LED is green, the LAN port is connected and/or active. Please note that these LAN ports are available on the X8DTU-6TF+ only. See the tables at right for more information.

TLAN LED: Yellow

LED States

State

Definition

 

 

Yellow Blinking

Gigabit LAN

 

Active

Yellow Solid

Gigabit LAN Link

On

(GLAN Con-

 

nected)

 

 

TLAN LED: Green

LED States

Color/State

Definition

Green Blinking

10 Gb LAN Active

 

 

Green On

10 Gb LAN Link (10

 

Gb LAN connected)

 

 