Chapter 5: Advanced Serverboard Setup

UIO Power Connector

A Universal I/O power connector

Universal I/O Power Connector

Pin Definitions

(UIOP) is located next to the UID button. This is a required connection for the riser cards installed on the serverboard. Connect the UIOP con- nector to the power supply to provide adequate power to the installed add- on cards installed for them to function properly. See the table on the right for pin definitions.

10Gb TLAN Ports and SFP+ Devices (X8DTU-6TF+)

Two 10Gb Ethernet ports (TLAN1/2) with Small_Form Factor Pluggable Device support are located at on the I/O backplane on the X8DTU-6TF+.

SAS BBU Connector

A SAS Battery Backup Unit (BBU) connector is located near the SAS ports. In the event of a power out- age, the BBU unit will provide backup power for SAS connection use.

(Part#: BTR-0018L-0000-LSI)

Pin# Definition

B1 P5V

B2 P5V

B3 P5V

B4 P5V

B5 P5V

B6 P5V

B7 P5V

B8 P5V

B9 P5V

B10 P5V

B11 N12V

B12 P3V3

STBY

B13 P3V3

STBY

B14 Ground

B15 Ground

B16 Ground

B17 Ground

B18 Ground

Pin # Definition

A1 P3V3

A2 P3V3

A3 P3V3

A4 P3V3

A5 P3V3

A6 P3V3

A7 P3V3

A8 P3V3

A9 P3V3

A10 P3V3

A11 P3V3

A12 P3V3

A13 P12V

A14 P12V

A15 P12V

A16 P12V

A17 P12V

A18 Ground

5-21

Page 69
Image 69