Chapter 5: Advanced Serverboard Setup
LED | Description |
LED1 | Power LED |
LED2 | UID LED |
LED3 | BMC Heartbeat LED |
LED4 | SAS Activity LED |
LED5 | SAS Heartbeat LED |
LED6 | SAS Error LED |
LED7 | UID LED |
5-8 Connector Definitions
ATX Power
Pin Definitions
ATX Power Connector
The primary ATX power supply con- nector meets the SSI EPS 12V speci- fication. Make sure that the orientation of the connector is correct. See the table on the right for pin definitions.
Pin# Definition
13+3.3V
14
15COM
16PS_ON
17COM
18COM
19COM
20Res (NC)
21+5V
22+5V
23+5V
24COM
Pin # Definition
1+3.3V
2+3.3V
3COM
4+5V
5COM
6+5V
7COM
8PWR_OK
95VSB
10+12V
11+12V
12+3.3V
Processor Power Connectors
JPW2 and JPW3 must also be con- nected to the power supply to provide power for the processor(s). See the table on the right for pin definitions.
Processor Power
Pin Definitions (JPW2/JPW3)
Pins |
| Definition |
1 through 4 |
| Ground |
| ||
5 through 8 |
| +12V |
| ||
|
|
|
Warning: To prevent damage to your power supply or serverboard, please use a power supply that contains a