Chapter 5: Advanced Serverboard Setup

Power Fail LED

The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions.

Overheat (OH)/Fan Fail/PWR Fail/UID

LED

Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat/Fan Fail/Power Fail and UID LED connections. The Red LED on pin 8 provides warnings of an overheat, fan failure or power failure. The Blue LED on pin 7 works as the UID LED indicator for the front panel UID switch located on pins 13~14 of JF1. When Jumper J_UID_OW is set to off (default), the Red LED takes precedence over the Blue LED. (See Page 2-19 for details.) Refer to the table on the right for pin definitions.

HDD/FP UID Switch

The HDD/UID Switch connections are located on pins 13/14 of JF1. Attach a hard-drive LED cable to display HDD or SATA activities. This connection can also be used as a front panel UID (Unit Identifi er) switch. The UID LED on Pin 7 of JF1 works in conjunction with this UID Switch. When the user presses and releases the UID switch, the UID LED will be turned on or off to indicate the location of the unit. (Refer to Page 2-11 for more details.)

PWR Fail LED

Pin Definitions

(JF1)

Pin# Definition

53.3V

6PWR Fail LED

OH/Fan Fail/ PWR Fail/Blue_UID

LEDPin Defi nitions (JF1)

Pin# Definition

7Blue_LED-Cathode(UID)/5.5V.SB

8OH/Fan Fail/PWR Fail/UID LED (Red)

OH/Fan Fail/PWR Fail

LED Status (Red LED)

State

Indication

 

 

Off

Normal

 

 

On

Overheat

 

 

Flashing

Fan Fail

 

 

HDD/UID Switch Pin Defi nitions (JF1)

Pin# Definition

13UID Signal/3.3V

14HDD Active

Power LED Connector

The Power LED connector is on pins 15 and 16 of JF1. See the table on the right for pin definitions.

Power LED

Pin Definitions

(JF1)

Pin# Definition

15PW_ON

16Ground

5-15

Page 47
Image 47
SUPER MICRO Computer AS2042G72RF4, 2042G-6RF Power Fail LED, Overheat OH/Fan Fail/PWR Fail/UID, HDD/FP UID Switch