SUPER MICRO Computer 6015W-NTR Enhanced x8 Detection, Demand Scrubbing, AMB Thermal Sensor

Models: 6015W-U 6015W-UR 6015W-NTR 6015W-NT

1 110
Download 110 pages 52.21 Kb
Page 81
Image 81

Chapter 7: BIOS

Enhanced x8 Detection

Select Enabled to enable Enhanced x8 DRAM UC Error Detection. The options are Disabled and Enabled.

Demand Scrubbing

Scrubbing is a process that allows the North Bridge to correct correctable memory errors found on an FBD memory module. When the CPU or I/O issues a demand read command, and the read data from memory turns out to be a cor- rectable ECC, it is corrected and sent to the original source. Memory is updated as well. Select Enabled to use Demand Scrubbing for ECC memory correction. The options are Enabled and Disabled.

High Temperature DRAM Operation

When set to Enabled, the BIOS will refer to the SPD table to set the maximum DRAM temperature. If disabled, the BIOS will set the maximum DRAM tempera- ture based on a predefi ned value. The options are Enabled and Disabled.

AMB Thermal Sensor

Select Enabled to activate the thermal sensor embedded in the Advanced Memory Buffer on a fully buffered memory module for thermal monitoring. The options are Disabled and Enabled.

Thermal Throttle

Select Enabled to enable closed-loop thermal throttling on a fully buffered (FBD) memory module. In the closed-loop thermal environment, thermal throttling will be activated when the temperature of the FBD DIMM module exceeds a predefi ned threshold. The options are Enabled and Disabled.

Global Activation Throttle

Select Enabled to enable open-loop global thermal throttling on a fully buffered (FBD) memory module to make it active whenever the number of activate control exceeds a predefi ned number. The options are Enabled and Disabled.

Force ITK Configuration Clocking

Select Enabled to confi gure FBD clock settings to support ITK testing. The op- tions are Disabled and Enabled.

Reserved Branch for ITK Test

This feature allows the user to specify the memory branch number to be reserved for ITK testing. The default setting is Branch 1.

7-13

Page 81
Image 81
SUPER MICRO Computer 6015W-NTR Enhanced x8 Detection, Demand Scrubbing, High Temperature Dram Operation, Thermal Throttle