Chapter 5: Advanced Serverboard Setup
HDD LED
The HDD (IDE Hard Disk Drive) LED connection is located on pins 13 and 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. Refer to the table on the right for pin defi nitions.
NIC1 LED
The NIC1 (Network Interface Control- ler) LED connection is located on pins 11 and 12 of JF1. Attach the NIC1 LED cable to display network activity. Refer to the table on the right for pin defi nitions.
NIC2 LED
The NIC2 (Network Interface Control- ler) LED connection is located on pins 9 and 10 of JF1. Attach the NIC2 LED cable to display network activity. Refer to the table on the right for pin defi nitions.
Universal Information LED
Connect an LED to pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure. These pins also work with the front UID indicator, which will activate as either a solid or fl ashing blue LED depending on whether the LED was activated via IPMI or the UID button. Refer to the tables on the right for pin defi nitions and status indicators.
HDD LED
Pin Definitions (JF1)
Pin# Defi nition
13Vcc
14HD Active
NIC1 LED
Pin Definitions (JF1)
Pin# Defi nition
11Vcc
12Ground
NIC2 LED
Pin Definitions (JF1)
Pin# Defi nition
9Vcc
10 Ground
Universal Info. LED
Pin Definitions (JF1)
Pin# Defi nition
7Vcc
8Control
Red LED Indications
State |
| Indication |
Solid |
| Overheat |
Blinking (fast) |
| Fan Fail |
| ||
Blinking (slow) |
| Power Fail |
| ||
|
|
|
| ||
Blue LED Indications | ||
|
|
|
State |
| Indication |
Solid |
| UID (via Button) |
| ||
Blinking |
| UID (via IPMI) |
| ||
|
|
|