Chapter 5: Advanced Serverboard Setup

HDD LED

The HDD (IDE Hard Disk Drive) LED connection is located on pins 13 and 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. Refer to the table on the right for pin defi nitions.

NIC1 LED

The NIC1 (Network Interface Control- ler) LED connection is located on pins 11 and 12 of JF1. Attach the NIC1 LED cable to display network activity. Refer to the table on the right for pin defi nitions.

NIC2 LED

The NIC2 (Network Interface Control- ler) LED connection is located on pins 9 and 10 of JF1. Attach the NIC2 LED cable to display network activity. Refer to the table on the right for pin defi nitions.

Universal Information LED

Connect an LED to pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure. These pins also work with the front UID indicator, which will activate as either a solid or fl ashing blue LED depending on whether the LED was activated via IPMI or the UID button. Refer to the tables on the right for pin defi nitions and status indicators.

HDD LED

Pin Definitions (JF1)

Pin# Defi nition

13Vcc

14HD Active

NIC1 LED

Pin Definitions (JF1)

Pin# Defi nition

11Vcc

12Ground

NIC2 LED

Pin Definitions (JF1)

Pin# Defi nition

9Vcc

10 Ground

Universal Info. LED

Pin Definitions (JF1)

Pin# Defi nition

7Vcc

8Control

Red LED Indications

State

 

Indication

Solid

 

Overheat

Blinking (fast)

 

Fan Fail

 

Blinking (slow)

 

Power Fail

 

 

 

 

 

Blue LED Indications

 

 

 

State

 

Indication

Solid

 

UID (via Button)

 

Blinking

 

UID (via IPMI)

 

 

 

 