Chapter 2: Server Installation

2-4 Rack Mounting Instructions

This section provides information on installing the SC827 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.

Note: This rail will fit a rack between 26" and 33.5" deep.

Separating the Sections of the Rack Rails

The chassis package includes two rail assemblies in the rack mounting kit. Each assembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself.

 

Figure 2-2. Separating the Rack Rails

1

Rail Assembly

Separating the Inner and Outer Rails

Extending the Rails

12

13

Quick-

Release Tab

14

Separating

the Inner Rail

Extension

1.Locate the rail assembly in the chassis packaging.

2.Extend the rail assembly by pulling it outward.

3.Press the quick-release tab.

4.Separate the inner rail extension from the outer rail assembly.

2-5

Page 21
Image 21
SUPER MICRO Computer 6026TT-GIBQRF Rack Mounting Instructions, Separating the Sections of the Rack Rails, Rail Assembly