Symbol Technologies AP-4131 manual Select Enter Admin Mode and type the password

Models: AP-4131

1 250
Download 250 pages 60.1 Kb
Page 155
Image 155

Configuring the AP

5.Select the correct communication port, typically Direct to Com1, along with the following parameters:

emulation

ANSI

baud rate

19200 bps

data bits

8

stop bits

1

parity

none

flow control

none

6.Select OK.

7.Press ENTER to display the Main Menu.

Symbol Access Point

 

 

MAIN MENU

Show System Summary

AP Installation

Show Interface Statistics

Special Functions

Show Forwarding Counts

Set System Configuration

Show Mobile Units

Set RF Configuration

Show Known APs

Set Access Control List

Show Ethernet Statistics

Set Address Filtering

Show RF Statistics

Set Type Filtering

Show Misc. Statistics

Set SNMP Configuration

Show Event History

Set Event Logging Configuration

Enter Admin Mode

 

8. Select Enter Admin Mode and type the password:

Symbol

The password is case-sensitive.