Configuring the AP

Ethernet Disables radio interface if no activity is detected

Timeout on the Ethernet line after the seconds indicated (30-255). The AP disassociates MUs and prevents further associations until it detects Ethernet activity. The default value 0 disables this feature. The 1 value detects if the 10/100Base-T line goes down.

If the value is set to 2 and the WLAP has connected to the Root AP, the WLAP sends a WLAP Alive BPDU on the Ethernet line every WLAP Hello Time seconds to allow WLAPs on the Ethernet line to detect its existence.

If the value is set to 3, the WLAP tracks the WLAP Alive BPDU. If the BPDU is missing for WLAP Hello Time seconds, the WLAP state changes to WLAP Lost on Ethernet. Once the WLAP Alive BPDU is detected, the WLAP resets and starts over.

When the Ethernet connection is broken the AP clears the MU table and disables the RF interface until the Ethernet connection comes up.

Telnet Logins Specifies if the AP accepts or rejects Telnet Logins. The default value is Enabled.