TS690R Installation Manual

System Installation

 

 

TRG - This is the bell trigger output which will switch to 0V on alarm and is rated at 500mA. This output can be programmed for SAB or SCB operation, as follows:

SAB: TRG - will switch to 0V on alarm and will provide a maximum of 500mA.

SCB: TRG - will provide a negative hold off (500mA), which is removed on alarm.

Control

Typical

Panel

External Sounder

 

H/O +

12V +

H/O -

0V

TR -

Tamper In

STB -

Tamper Out

TRG -

Strobe +ve

 

Strobe -ve

 

Trigger -ve

Figure 11. End of Line Wiring

Installing a 515r PIR

Activity LED

The 515r Passive infra Red (PIR) is an indoor detector designed to work with the TS690R control panel. The detector has a fan shaped sensitive area approximately 10 metres in radius.

Fixing hole cutouts

Tamper Battery case

Auxiliary Tamper

These two terminals provide tamper protection to auxiliary devices such as power supplies, extension loudspeakers etc. If they are not used they must be linked out.

Extension Loudspeakers

Up to two extension loudspeakers can be connected across the [SPK+] and [H/O-] terminals on the control panel PCB. The volume for the loudspeaker is controlled by VR1 “Speaker Volume”.

SPK+

H/O -

1 x 16 Ohm Loudspeaker

SPK+

H/O -

2 x 16 Ohm Loudspeakers

Figure 12. External Sounder Connections

 

+

 

+

Back

Body

Siting the 515r PIR

You can mount the unit either flat against the wall, or in a corner. The area covered by the detector is shown below:

10m

10m

2m

15