TS690R Installation Manual | System Installation |
|
|
TRG - This is the bell trigger output which will switch to 0V on alarm and is rated at 500mA. This output can be programmed for SAB or SCB operation, as follows:
SAB: TRG - will switch to 0V on alarm and will provide a maximum of 500mA.
SCB: TRG - will provide a negative hold off (500mA), which is removed on alarm.
Control | Typical |
Panel | External Sounder |
| |
H/O + | 12V + |
H/O - | 0V |
TR - | Tamper In |
STB - | Tamper Out |
TRG - | Strobe +ve |
| Strobe |
| Trigger |
Figure 11. End of Line Wiring
Installing a 515r PIR
Activity LED
The 515r Passive infra Red (PIR) is an indoor detector designed to work with the TS690R control panel. The detector has a fan shaped sensitive area approximately 10 metres in radius.
Fixing hole cutouts | Tamper Battery case |
Auxiliary Tamper
These two terminals provide tamper protection to auxiliary devices such as power supplies, extension loudspeakers etc. If they are not used they must be linked out.
Extension Loudspeakers
Up to two extension loudspeakers can be connected across the [SPK+] and
SPK+
H/O -
1 x 16 Ohm Loudspeaker
SPK+
H/O -
2 x 16 Ohm Loudspeakers
Figure 12. External Sounder Connections
| + |
| + |
Back | Body |
Siting the 515r PIR
You can mount the unit either flat against the wall, or in a corner. The area covered by the detector is shown below:
10m
10m
2m
15