Output Types |
|
|
|
|
|
| |
No. | Output Type |
| No. | Output Type |
| No. | Output Type |
000 | Bell On |
| 016 | Part Set C Selected |
| 032 | Duress Alarm |
001 | Strobe On |
| 017 | Part Set B Selected |
| 033 | System Part Set |
002 | Switch 12V |
| 018 | Part Set A Selected |
| 034 | Battery Fault |
003 | Detector Reset |
| 019 | Full Set Selected |
| 035 | Set Fail |
004 | Walk Test |
| 020 | Tamper Fault |
| 036 | System Open |
005 | Alarm |
| 021 | Signal Jammed |
| 037 | 24hr Omit |
006 | P.A. |
| 022 | Mains Off |
| 038 | Sounder control |
007 | Fire |
| 023 | Exit / Entry |
| 039 | Engineer Reset Required |
008 | System Set |
| 024 | Test Fail |
| 040 | General fault |
009 | Code Accepted |
| 025 | First Knock |
| 041 | Battery test |
010 | 24 Hour |
| 026 | Abort |
| 042 | FOB active |
011 | Second Alarm |
| 027 | Timed output |
| 043 | Full set |
012 | Courtesy Light |
| 028 | Chime mimic |
| Circuits Mimics 01 - 38 | |
013 | Engr On Site |
| 029 | 2nd Entry |
| Circuit Alarms 01 - 38 | |
014 | Ccts Omitted |
| 030 | Entry |
|
|
|
015 | Auxiliary |
| 031 | Exit |
|
|
|
Circuit Types |
| System Timers |
| Configuration |
| User Types | ||||
| Circuits |
| No | Timer |
| No | Option |
| 1 | Master |
No | Type |
| 00 | 2nd Alarm Time |
| 00 | Bell is an SAB |
| 2 | Standard |
0 | Not Used |
| 01 | No. |
| 01 | User 1 Limited |
| 3 | Holiday |
1 | Night |
| 02 | Settle Time. |
| 02 | Fire signals always |
| 4 | Set Only |
2 | 24 Hour |
| 03 | P. Set Comms Dly |
| 03 | Silent 24hr ccts |
| 5 | Reset Only |
3 | PA Silent |
| 04 | Exit Time |
| 04 | Enable duress |
| 6 | Duress |
4 | PA Audible |
| 05 | Entry Time |
| 05 | Invert Abort O/P |
| 7 | P.A. Code |
5 | Fire |
| 06 | Bell Duration |
| 06 | Monitor Polling Signals |
|
|
|
6 | Auxiliary |
| 07 | Bell Delay |
| 07 | User reset |
|
|
|
7 | Final Exit |
| 08 | D.Knock Delay |
| 08 | Fob unset with entry |
|
|
|
8 | Exit Terminator |
| 09 | Test Time |
| 09 | Passcode + ENT |
|
|
|
9 | Key Point |
| 10 | Second Entry Time |
| 10 | Loud Chime tones |
|
|
|
| Attributes |
| 11 | Abort Delay |
| 11 | Do battery test |
|
|
|
No | Type |
| 12 | Monitor Delay |
| 12 | F.Exit is NIGHT in P.Set |
|
|
|
1 | Access |
| 13 | Part Set Bell Delay |
| 13 | Mimic Alarm & Faults |
|
|
|
2 | Double Knock |
| 14 | Courtesy Duration |
| 14 | Invert Panel Outputs |
|
|
|
3 | Test |
| 15 | AC off Delay |
| 15 | Allow set with AC off |
|
|
|
4 | Omit |
|
|
|
| 16 | Tampers user reset |
|
|
|
5 | Reset |
|
|
|
| 17 | Enable Jamming |
|
|
|
Setting Modes |
|
|
|
| ||||||
6 | Monitor |
|
|
|
|
|
|
| ||
7 | Entry |
| 1 | Final Exit |
|
|
|
|
|
|
8 | Chime |
|
|
|
|
|
|
|
|
|
| 2 | Exit Terminator |
|
|
|
|
|
| ||
|
|
| 3 | Timed Exit |
|
|
|
|
|
|
|
|
| 4 | Instant |
|
|
|
|
|
|
|
|
| 5 | Deferred |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47