TS690R Installation Manual

System Installation

 

 

NVM Defaults

Section

 

Option

Default

 

 

 

User Codes

User 00 Engineer

1234

 

 

 

 

User 01 Master

5678

 

 

 

 

User 02 - 10

Not Used

 

 

 

 

Panel Output 1

Walk Test

 

 

 

 

Panel Output 2

Courtesy Light

 

 

 

Panel

Panel Output 3

SW12V

 

 

 

Panel Output 5

Code Accepted

Outputs

 

 

 

Panel Output 6

Code Accepted

 

 

 

 

 

Panel Output 7

Code Accepted

 

 

 

 

Panel Output 8

Code Accepted

 

 

 

Circuits

Circuits 01 - 38

Not Used

 

 

 

 

 

00

2nd Alarm Time

005 seconds

 

 

 

 

 

01

No of Re-arms

003

 

 

 

 

 

02

Settle Time

005 seconds

 

 

 

 

 

03

Part Set Coms Dly

030 seconds

 

 

 

 

 

04

Exit Time

030 seconds

 

 

 

 

 

05

Entry Time

015 seconds

 

 

 

 

 

06

Bell Duration

020 minutes

 

 

 

System Timers

07 Bell Delay

000 minutes

08

D-Knock Delay

008 seconds

 

 

 

 

 

 

09

Test Time

014 days

 

 

 

 

 

10

Second Entry

015 seconds

 

 

 

 

 

11

Abort Delay

180 seconds

 

 

 

 

 

12

Monitor Duration

010 seconds

 

 

 

 

 

13

Part Set Bell Delay

030 seconds

 

 

 

 

 

14

Courtesy Duration

060 seconds

 

 

 

 

 

15

AC Off Delay

000

 

 

 

 

Section

 

Option

Default

 

 

 

 

Full Set

Final Exit Setting

 

 

 

Setting

Part Set A

Timed Exit

Modes

Part Set B

Timed Exit

 

 

 

 

 

Part Set C

Timed Exit

 

 

 

Rem Reset

Algorithm

004

 

 

 

 

 

00

Bell is an SAB

Yes

 

 

 

 

 

01

User 1 Limited

No

 

 

 

 

 

02

Fire Signals All

Yes

 

 

 

 

 

03

Silent 24hr Circuits

No

 

 

 

 

 

04

Enable Duress

No

 

 

 

 

 

05

Invert Abort

No

 

 

 

 

 

06

Monitor Polling Sig

No

 

 

 

 

 

07

User Reset

No

 

 

 

Configuration

08 Fob unset with entry

Yes

09 Passcode + ENT

No

 

 

 

 

 

 

10

Loud Chime Tones

Yes

 

 

 

 

 

11

Do Battery Test

No

 

 

 

 

 

12

Final Exit is Night

No

 

 

 

 

 

13

Mimic Alms & Flts

No

 

 

 

 

 

14

Invert panel outputs

No

 

 

 

 

 

15

Set with AC off

No

 

 

 

 

 

16

Tampers user reset

No

 

 

 

 

 

17

Enable jamming

Yes

 

 

 

 

21