TS690R Installation Manual

Engineer’s Menu 1

 

 

Configuration [1.9]

The configuration options are as follows:

00Bell Is an SAB

When programmed as “Yes” the control panel bell output applies 0V when active. When programmed as “No” the control panel bell output removes 0V when active. (Default = Yes)

01User 1 Limited

When programmed as “Yes” user 1 is disabled from option 8 (Configure Part-Sets) in user menu 2. When programmed as “No” user 1 has access to all user menus and options. (Default = Yes)

02Always Signal Fire

When programmed as “Yes” fire alarm activations are signalled to the ARC at all times. When programmed as “No” fire alarm activations are signalled to the ARC only when the system is full set. (Default = Yes)

03Silent 24hr Circuits

When programmed as “Yes” 24hr circuit are silent. When programmed as “No” 24hr circuits are audible. (Default = No)

04Enable Duress

When programmed as “Yes” the reversal of the first two digits on any passcode will generate a duress alarm. When programmed as “No” the reversal of the first two digits on any passcode will NOT generate a duress alarm. (Default = No)

05Invert Abort O/P

When programmed as “Yes” the abort output is normally active and deactivates for 5 seconds when an alarm is aborted. When programmed as “No” the abort output is normally inactive and activates for 5 seconds when an alarm is aborted. (Default = No)

06Monitor Polling Signals

When programmed as “Yes” the system will monitor the polling signals from all wirefree detectors. This is transmitted by each detector every 29 minutes. If this option is enabled and two consecutive polling signals are not detected by the control panel, the panel will generate a tamper alarm. When programmed as “No” the system will not monitor polling signals from wirefree detectors. (Default = Yes)

07User Reset

When programmed as “Yes" alarms can be reset by the user. When programmed as ”No" alarms can only be reset by the engineer or via remote reset. (Default = No)

08Fob can only Unset with Entry

When programmed as “Yes" the 525r remote setting fob can only be used to unset the system after the entry timer is started. When programmed as ”No" the 525r remote setting fob can be used to unset the system at any time. (Default = Yes)

09Passcode and "ENT"

When programmed as “Yes", all passcodes require an additional press of the [ENT] key to gain access to the system. When programmed as ”No", access to the system only requires the entry of the passcode. (Default = No)

10Loud Chime Tones

When programmed as “Yes” the chime tones are always at full volume. When programmed as “No” the chime tones are at the level set by VR1 on the main PCB. (Default = Yes)

11Do Battery Test

When programmed as "Yes" the control panel battery and any monitored PSU batteries are tested every hour and when exiting the engineer's mode. When programmed as "No" the control panel battery and any monitored PSU batteries are not tested. (Default = No)

12F.Exit is Night

When programmed as “Yes" final exit circuits change to night circuits when the system is part set. When programmed as ”No" final exit circuits remain as final exit circuits when the system is part set. (Default = No)

13Mimic Alarms and Faults

When programmed as “Yes” any outputs programmed as the type "Circuit Alarm" will activate when the relevant circuit is in alarm or in a fault condition. When programmed as “No” any outputs programmed as the type "Circuit Alarm" will activate when the relevant circuit is in alarm. (Default = No)

31