Do
λMake sure there is less than 10mm between the magnet and transmitter body with the door or window closed.
λMake sure the arrow on the magnet aligns with the mark moulded into the side of the case with the door/ window closed.
Do NOT mount the unit
λOn the hinged edge of the door..
λNear the floor.
λClose to or on large metal structures.
λCloser than one metre to mains wiring and metal water or gas pipes.
λInside steel closures.
λNext to electronic equipment, particularly computers, photocopies or other radio equipment.
Using the internal Reed Switch
If you plan to use the internal reed switch the YOU MUST CUT THE INTERNAL REED SHUNT LINK. However, if at a later date you wish to connect hard wired contacts you must
Installation
1.Open the transmitter by inserting a small flat bladed screwdriver in the slot at the bottom of the case.
2.Install two "AAA" size alkaline batteries (not supplied). Do not use rechargeable (Nickel Cadmium) batteries, because they are 1.2V and not 1.5V.
3.Learn the detector (see "Adding Devices" on page 33).
TS690R Installation Manual
4.Mount the transmitter back box in its required position using two type "C" 15mm domehead screws.
5.Make sure the back is flush against the surface and pushes the tamper bar in far enough to activate the tamper switch.
6.Fit the body of the transmitter to the back box.
Connecting External Door Contacts
You can wire external normally closed devices to the 535r universal transmitter. You can connect several contacts in series, but the control panel will treat them all as one zone. Do not use more than 10 metres total cable length from the 535r to the last external contact.
1.Remove the wire links from the terminal connector.
2.Connect the normally closed contacts as shown:
Tamper | 5 6 | 4 | 3 | Alarm |
|
|
| ||
circuit |
|
|
| circuit |
3.Make sure the internal reed shunt link is intact.
DO NOT CUT.
If you remove the external contacts at a later date, make sure you replace the wire links on the alarm and tamper terminals.
Testing
1.Put the TS690R control panel into walk test mode (user code + [ENT] + [2]).
2.Hold The detector in place.
3.Trigger the tamper.
4.Make sure the control panel receives an alarm.
5.Choose another site for the detector if the panel does not receive the signal.
6.Press [ESC] twice when you have finished testing, to put the control panel back in the open mode.