Engineer’s Menu 1 | TS690R Installation Manual |
|
|
The setting mode for full set and each part set can be configured to the following setting modes:
1Final Exit
The system will set when the final exit circuit is triggered and when the settle timer expires.
2Exit Terminator
The system will set when the final exit circuit is triggered, the exit terminator button is pressed and after the settle timer has expired.
3Timed Exit
The system will set when the exit timer expires or if the exit terminator button is pressed.
4Instant
The system will set instantly.
5Deferred
As timed exit, however, if any circuits are activated during the exit procedure the exit timer is restarted.
E / MENU 1
6
SET MOD?
Enter group:
0= Full Set
A = Part Set A B = Part Set B C = Part Set C
e.g. 0 for full set
BY F / E
Select Set Mode:
1= Final Exit
2= Exit Terminator
3 = Timed Exit
4 = Instant
5 = Deferred
e.g. 3 for timed exit
BY T / E
Setting Modes Flowchart
When the system is programmed for “Engineer Reset” the requirement to send an engineer to site can be overridden by the user by using the “Remote Reset” facility. If an alarm is generated the system will respond with a four digit “seed” code which the user quotes to the Alarm Receiving Centre or alarm company. The “seed” code is then entered into a decoder and a unique “Remote Reset” code is generated. This is passed back to the user and on entering the “Remote Reset” code, the system is reset.
The “Remote Reset” code is generated using an algorithm identified by a 3 digit number. Alternative algorithms can be selected but these must correspond to that used by the ARC (or alarm company) otherwise the “Remote Reset” code will be incorrect. (Default = 004)
E / MENU 1
8
ALG 004
Enter new No.
e.g. 010
ALG 010
Remote Reset Algorithm Flowchart