= Part set C

Engineer's Menu 2

TS690R Installation Manual

 

 

Configure Part Sets [2.8]

The TS690R can be configured to have up to three parts set modes (Part Set A, Part Set B and Part Set C). This option allows the engineer to configure each part set mode. Within each part set mode you must designate which circuits will remain armed and which circuits will be omitted. When the user selects the relevant part set mode the system only arm the circuits that are designated as armed and isolate the circuits that are designated as omitted.

Only the circuit types “Night”, “Final Exit” and “Exit terminator” can be designated as omitted.

If the system uses a 525r remote setting device the "NIGHT" button is always assigned to "Part Set A".

E / MENU 2

8

P / SET A

Select part set mode:.

A = Part set A

B = Part set B

C

01 - ARMED

A= Next circuit

B= Alternate Armed/Omitted C = Previous circuit

e.g. Press B

01 - OMIT

Repeat for remaining circuits

View System Log [2.9]

The engineer can use this option to view the system log. The [A] and [C] keys allow you to scroll backwards and forwards through the log events.

E / MENU 2

9

USER 00

A= Scroll backwards

B= Alternate event, time & date C = Scroll forwards

ALARM 03

A= Scroll backwards C = Scroll forwards

View System Log Flowchart

Configure Omits Flowchart

38