Engineer’s Menu 1 | TS690R Installation Manual |
|
|
Outputs 1 - 3 on the control panel and remote keypad outputs 5 - 8 can be programmed to any of the output types shown on pages 24 to 26. In addition, all panel outputs can be inverted, see “Configuration option 14” on page 32.
E / MENU 1
1
PANEL -
Enter output No. 1 - 8
e.g. 1
No Type/Description
000Bell On
Activates when the main Bell trigger is on and deactivates at the end of the Bell Duration time or when the alarm is cancelled by the user.
001Strobe On
Activates when the Strobe trigger is on, and deactivates when the alarm is cancelled by the user.
002Switch 12V
Activates when the system is set and deactivates when an alarm occurs or the system is unset. This output is normally used for latching detectors.
Type No.
004
003 Detector Reset |
Normally active at all times and deactivates |
for 3 seconds when a valid passcode is |
Enter new output type e.g. 021
021
Panel Outputs Flowchart
entered prior to setting the system. This output |
is normally used for detector that required |
power to be removed in order to reset them, |
e.g., smoke detectors. |
004Walk Test
Activates when the "Walk Test" option is selected and deactivates when the "Walk Test" option is finished.
005Alarm
Activates when an intruder alarm is detected and deactivates when the alarm is reset or aborted.
006P.A.
Activates when a PA alarm is detected and deactivates when the alarm is reset.
007Fire
Activates when a Fire alarm is detected and deactivates when the alarm is reset.
008System Set
Activates when any ward is set and deactivates when the system is fully unset.
009Code Accepted
Activates for 10 seconds following entry of any valid passcode.
01024 Hour
Activates when a 24Hr alarm is detected and deactivates when the alarm is reset.
24