System Installation

TS690R Installation Manual

 

 

Pre Power-Up Checks

Once the system is installed, but prior to powering-up, give the system one final check to ensure that:

1.The wiring conforms to the requirements detailed in this manual and that all interconnections are correct (A to A, B to B etc.).

2.All system cables are kept clear of mains supply cables, telephone cables and R.F. cables. It is recommended that cable ties be used to keep cables separated.

3.Verify that maximum cable lengths and resistance's are not exceeded.

4.Mains power supply cables to the system are connected to an un-switched fused spur.

Initial Power-Up

To power the system for the first time:

1.Place a small screwdriver blade between the pins on the control panel PCB, marked “FACTORY RESET”. This will ensure the factory default parameters are set, see page 21.

2.Switch on the 240V mains supply and remove the screwdriver blade from the factory restarts pins.

3.Check that the control panel and remote keypads show “LID TAMP”. The internal sounder and remote keypad sounders will operate.

4.Enter the engineers passcode (default 1234) to silence the sounders.

5.Connect the standby battery.

6.Enter the engineers passcode (default 1234) to select engineer's menu 1. Once you have completed the “Power-up Checks” you can continue to program the system.

Power-Up Checks

When the initial power-up checks have been completed, check the following:

1.Switch off the 240V mains supply and measure the DC voltage at each remote keypad and ensure the voltage is greater than 11V whilst the system is powered from its standby battery.

2.Switch on the 240V mains supply and measure the DC voltage between the mains earth connection and AUX +12V. Then measure the DC voltage between the mains earth connection and AUX 0V. In both cases the measurement should be 1V or less. If the voltage is greater than 1V, the system has an “Earth Fault” and all cables should be checked for isolation to Earth.

20