TS690R Installation Manual | System Installation |
|
|
525r Remote Setting Device
|
| Activity LED | |
PANIC | ARM |
| |
NIGHT | Part set button | ||
| |||
| OFF |
|
5
The 525r remote setting device can be used to set, part set (part set A only) and unset the alarm system. In addition, pressing the "ARM" and "OFF" at the same time will cause a panic alarm. The 525r is assigned as a detection circuit.
Learning
See "Adding Devices" on page 33.
Changing the Battery
The battery used in the 525r is a Duracell DL 1/3N or CR 1/3N or K58L (Alkaline). The battery can be obtained from normal high street stockists.
1.Undo the screw holding down the battery compartment cover.
2.Slide back the cover.
3.Replace the battery (make sure the battery polarity is correct).
4.Replace the cover and tighten the screw.
Battery +ve Terminal
Installing a 535r Universal Transmitter
Activity LED
The 535r universal transmitter is designed to work with the TS690R control panel. The transmitter signals an alarm when the associated magnet moves away from the case, and sends a restore signal when the magnet is
Terminal |
|
|
Block | Internal Reed |
|
|
| |
Internal | Shunt Link |
|
|
| |
Reed |
|
|
Fixing |
| Battery |
Hole | + | Case |
|
| |
Tamper |
|
|
Bar |
| Tamper |
|
|
+
Fixing
Hole
Back | Body |
Siting the 535r Universal Transmitter
Where possible, mount the unit close to the top of the
17