TS690R Installation Manual

Engineer’s Menu 1

 

 

No Type/Description

011Second Alarm

Activates when a different detector causes an alarm and remains active for the duration of the "2nd Alarm Time". This output is normally used for an ALARM CONFIRMATION signal.

012Courtesy Light

Activates during entry and when any remote keypad is used. The duration of this output is controlled by the setting of the "COURTESY DUR" timer.

013Engineer On Site

Activates when the engineer’s passcode is entered and deactivates when a user passcode is entered.

014Circuits Omitted

Activates when any circuit is omitted and deactivates when all circuits are reinstated.

015Auxiliary

Activates when an Auxiliary alarm is detected and deactivates when the alarm is reset.

016Part Set C SelectedActivates when "Part Set C" is selected. Deactivates when the system is unset.017Part Set B SelectedActivates when "Part Set B" is selected. Deactivates when the system is unset.018Part Set A SelectedActivates when "Part Set A" is selected. Deactivates when the system is unset.019Full Set SelectedActivates when "Full Set" is selected. Deactivates when the system is unset.020Tamper Fault

Activates when a Tamper alarm is detected and deactivates when the alarm is reset.

021Signal Jammed

Activates when the control panel detects a continuous radio signal for 30 seconds on the same frequency used by the detectors. Deactivates when the signal is removed.

022Mains Off

Activates when mains power is removed and deactivates when the mains power is restored.

023Exit / EntryActivates when the panel is in the exit or entry mode.

No Type/Description

024Test FailActivates when a circuit fails test,, deactivates when reset by the engineer.025First Knock

Activates when a double knock circuit is activated for the first time. Deactivates when the circuit is activated for the second time or when the system is reset.

026Abort

Activates for 5 seconds after an alarm is aborted by the user. The period in which the alarm may be aborted is set by the "Abort Delay" see System Timers.

027Timed Output

Activates when a "Monitored" circuit is triggered and remains active for the duration of the "Monitor Delay" see System Timers.

028Chime Mimic

Activates for 2 seconds when a circuit that is programmed as "chime" is activated.

0292nd Entry

Activates when the second entry timer is started and deactivates when the second entry timer expires.

030EntryActivates when the panel is in the entry mode.031ExitActivates when the panel is in the exit mode.032Duress Alarm

Activates when a duress passcode is entered and deactivates when the duress alarm is reset.

033System Part Set

Activates when the system is part set fails to set and deactivates when the system is fully set or unset.

034Battery Fault

Activates when a battery fault occurs and deactivates when the battery fault is cleared.

035Set Fail

Activates when the system fails to set and deactivates when the set fail condition is reset by the user.

036System Open

Activates when the system is unset,, deactivates when the system is fully set or part-set.

25