TroubleshootingGuideModel PH90 72
Problem Shake Side
Probable Cause
Soft Serve Side
Probable Cause
Either Side
Probable Cause
Corrective Action Page
Ref.
18. Machine will not
run when in the
AUTO mode.
(Cont’d.)
c. Circuit breaker
OFF or blown
fuse.
c. Turn the breaker ON or replace
the fuse, and clear the fault.
-- -- --
d. Low on mix. The
MIX OUT light is
ON.
d. Add mix to the mix hopper and
press the AUTO keypad.
39
e. Water is turned
OFF on water
cooled units.
e. Turn water ON, and clear the
fault.
-- -- --
19. Air compressor
runs too oftenfor
normal usage.
a. Air leak in the
system.
a. Use a soap solution to locate
the leak and repair.
-- -- --
20. Liquid Crystal
Display is blank.
a. Machine is
unplugged.
a. Plug into wall receptacle. -- -- --
b. Circuit breaker is
OFF or blown
fuse.
b. Turn the circuit breaker ON or
replace the fuse, and clear the
fault.
-- -- --
c. Component
failure.
c. Call service technician. -- -- --
d. LCD intensity
needs adjusting.
d. Call service technician. -- -- --
21. Product is not
feeding into the
freezing cylinder.
a. The mix inlet hole
is frozen up.
a. The hopper temperature needs
adjustment. Call service
technician.
-- -- --
22. The draw handle
does not close.
a.Mixisonthe
sensing eye.
a. Clean the sensing eye. -- -- --