Technicolor - Thomson LDK 20(S) technical manual Black indicator level

Models: LDK 20(S)

1 90
Download 90 pages 17.83 Kb
Page 49
Image 49

Video Miscellaneous Board

Black indicator level

25.Use the controls at the rear of the camera to set the white indicator level for the monitoring output by navigating through the menu system to menu number 318 and setting the value to 85.

26.Connect oscilloscope terminated with 75 Ohm to the VF output of the camera.

27.Adjust the black level of the indicators of the VF output signal to the same level as the blanking.

Measure at:

VF output

Adjust with:

ZR47

Required result:

Correct:

 

0.2V

10µS

100

 

90

 

10

 

0%

 

 

VB+714mV

Incorrect:

 

0.2V

10µS

100

 

90

 

10

 

0%

 

 

VB+714mV

28.On connector B of the service extender remove the short circuits on the input to Video Processor 1 Board by disconnecting the jumpers fromB7 to B9

B11 to B13

B17 to B19

Reconnect

A7 to B7

 

A9 to B9

 

A11 to B11

 

A13 to B13

 

A17 to B17

 

A19 to B19 on connector B of the service extender.

Adjustments

Technical Manual LDK 20(S) - Studio Camera

4-23

Page 49
Image 49