Encoder Board NTSC

Burst timing

23.Observe waveform monitor or oscilloscope and adjust the burst position so that it is 5.3µS from the leading edge of the line synchronisation.

Measure at:

CVBS out

Adjust with:

ZR209

Required result:

5.3µS

Correct:

 

50mV

1µS

100

 

90

 

10

 

0%

 

 

t+5.3µs 178kHz

5.3µs

 

Genlock free-running preset

24.Remove genlock signal from camera.

25.Turn lock range potentiometer ZR215 fully counterclockwise.

26.Observe colour monitor, waveform monitor or vectorscope and adjust oscillator preset potentiometer for minimum free-running.

Measure at:

CVBS out

Adjust with:

ZR216

Required result:

Minimum free-

running speed

I/Q bar amplitude

27. Adjust the I and Q bars for an amplitude of 286mV (40 IRE).

Measure at:

CVBS out

CVBS out

Adjust with:

ZR207

ZR201

Required result:

I-bar amplitude

Q-bar amplitude

Correct:

 

 

 

%

 

 

 

VOLT

120

 

 

 

 

100

 

R

cy

0.7

80

g

 

MG

 

 

 

V

 

 

 

 

 

60

 

75

 

 

 

YL

100

b

5

40

 

 

 

 

U

0

 

 

 

 

20

yl

 

B

-5

 

 

 

 

0

20

 

G

mg

 

 

 

 

 

43

 

r

CY

0.3

 

 

 

 

I bar

Q bar

 

28. Switch off power and return encoder board to its position in the camera.

Adjustments

Technical Manual LDK 20(S) - Studio Camera

4-49

Page 75
Image 75
Technicolor - Thomson LDK 20(S) technical manual Bar amplitude, Adjust the I and Q bars for an amplitude of 286mV 40 IRE