Introduction Teledyne API T703/T703U Calibrator Operation Manual

20

1.2. OPTIONS

Option Option

Number Description/Notes

Rack Mounting For mounting the analyzer in standard 19” racks
20A Rack mount brackets with 26 in. (660 mm) chassis slides
20B Rack mount brackets with 24 in. (610 mm) chassis slides
21 Rack mount brackets only
The T703/T703U WEIGHS about 16.3 kg (36 pounds). To avoid personal injury we recommend
two persons lift and carry the calibrator.
Disconnect all cables and tubing from the calibrator before carrying it.
Carrying Handle Strap to carry unit
29 Carrying handle (strap)
Parts Kits Spare parts and expendables for 1-year operation
42A Kit, Spares for One Unit
Communications For remote serial, network and Internet communication with the analyzer.
Type Description
60A RS-232
Shielded, straight-through DB-9F to DB-25M cable, about 1.8 m long. Used to
interface with older computers or code activated switches with DB-25 serial
connectors.
60B RS-232
Shielded, straight-through DB-9F to DB-9F cable of about 1.8 m length.
60C Ethernet Patch cable, 2 meters long, used for Internet and LAN communications.
Cables
60D USB
Cable for direct connection between instrument (rear panel USB port) and
personal computer.
USB Port 64A For rear panel connection to personal computer.
RS-232 Multidrop 62
Multidrop/LVDS card seated on the analyzer’s CPU card.
Each instrument in the multidrop network requres this card and a communications cable
(Option 60B).
External Valve Driver Capability - For driving up to eight, 8-watt valves
48A 12V External Valve Driver Capability
48B 24V External Valve Driver Capability
NIST Traceable, Primary Standard Certification for use as a Primary Ozone Standard if purchased with the O3
generator and photometer options, 1A and 2A, respectively.
95C Calibration to NIST-SRP
95D Calibration as aTransfer Standard (6x6)
The Model T703 can be used as a Primary Ozone Standard. For this application the performance of the T703 Photometric
Calibrator is calibrated to Standard Reference Photometer (SRP) Calibrators ordered with this option are verified and
validated in accordance with the procedures prescribed by the U.S. Environmental Protection Agency (EPA) under Title 40
of the Code of Federal Regulations, Part 50, Appendix D (40 CFR Part 50).
Special Features Built in features, software activated
N/A
Maintenance Mode Switch, located inside the instrument, places the analyzer in
maintenance mode where it can continue sampling, yet ignore calibration, diagnostic, and
reset instrument commands. This feature is of particular use for instruments connected to
Multidrop or Hessen protocol networks.
Call Customer Service for activation.
N/A
Second Language Switch activates an alternate set of display messages in a language
other than the instrument’s default language.
Call Customer Service for a specially programmed Disk on Module containing the second language.

07223C DCN6572